第1回
横型ポンプの振動診断の実績と今後
著者:
堀井 一明,Horii KAZUAKI,小林 秀壽,Kobayashi HIDETOSHI,鶴来 俊弘,Tsurugi TOSHIHIRO,代田 寿彦,Shirota TOSHIHIKO
発刊日:
公開日:
キーワードタグ:
In Hamaoka nuclear power station, Condition Based Maintenance (CBM), which uses vibration diagnosis technology, has been introduced for some rotational devices such as horizontal type pumps or fans. Until now, a lot of instances, which include predicting a failure of bearing by detecting an upwarc tendency of vibration, and reducing an oscillation by adding adequate oil following a detection of insufficient bearing lubricant, show that CBM has an adequate predictive function as preventive maintenance metho...
英字タイトル:
Current and Future Diagnosis of vibration in horizontal type pumps
第7回
浜岡5号機 駿河湾の地震に伴うタービン保全復旧報告
著者:
長谷川 義朗,Yoshirou HASEGAWA,堀井 一明,Kazuaki HORII,青木 薫,Kaoru AOKI,柴下 直昭,Naoaki SHIBASHITA
発刊日:
公開日:
キーワードタグ:
Hamaoka Nuclear Power Station Reactor No. 5 was automatically shut down when an earthquake occurred in Suruga Bay on August 11, 2009. A special maintenance plan for inspections to verify the soundness of equipment and facilities in Hamaoka Nucle ar Power Station was formulated following the earthquake. The main steam turbine in Hamaoka Nuclear Power Station Reactor No. 5 was inspected based on the plan. The middle standard bearing box, which had the thrust bearing of the turbine was fou nd to lift slightly...
英字タイトル:
Maintenance Report of Hamaoka Nuclear Power Station Reactor No. 5 Turbine Damaged by Suruga Bay Earthquake
第10回
浜岡原子力発電所5号機 主復水器細管損傷の影響調査(その2)
著者:
市川 義浩,Yoshihiro ICHIKAWA,釘本 三男,Mitsuo KUGIMOTO,三谷 和己,Kazumi MITANI,堀井 一明,Kazuaki HORII,直井 万隆,Banryu NAOI
発刊日:
公開日:
キーワードタグ:
In the process of achieving cold shutdown following the shutdown of Hamaoka Nuclear Power Station Unit 5 on May 14, 2011, large quantities of seawater flowed into the reactor and other facilities due to main condenser tubes which had broken. The investigations focusing on corrosion of materials had been conducted through various methods, observation of equipments, material tests, cleaning tests, and inspection of RPV and its components. Based on these investigations, we had evaluated the impact on the...
英字タイトル:
Effect of sea water intrusion from main condenser, damaged by break on reactor core internals, Hamaoka Unit 5(No.2)